{"product_id":"42u-serverkast-met-geperforeerde-deuren-800x1000x2050mm-bxdxh-zwart","title":"42U server cabinet with perforated doors 800x1000x2050mm (WxDxH) black","description":"\u003ch3\u003e \u003cspan\u003eTechnical details\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv class=\"twocols\" id=\"techdetails-content\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eLoad capacity: 1000 kg\u003c\/li\u003e\n\n\u003cli\u003e Protection class IP20\u003c\/li\u003e\n\n\u003cli\u003e Front and back doors made of 70% perforated steel\u003c\/li\u003e\n\n\u003cli\u003e The perforated section in the front door is bent outwards\u003c\/li\u003e\n\n \u003cli\u003eLocking system with rotating lever on front and rear door (incl. profile half-cylinder lock)\u003c\/li\u003e\n\n\u003cli\u003e 230° opening angle of the front and rear doors\u003c\/li\u003e\n\n\u003cli\u003e Double wing back door\u003c\/li\u003e\n\n\u003cli\u003e Front door with 4-point locking and rear door with 3-point locking\u003c\/li\u003e\n\n\u003cli\u003e Horizontally split side panels (two per side), lockable and removable\u003c\/li\u003e\n\n\u003cli\u003e incl. 4 adjustable feet and 4 castors, which are already mounted under the cabinet (front wheels are lockable)\u003c\/li\u003e\n\n\u003cli\u003e 483mm (19\") profile rails mounted to the front and back inside the cabinet, galvanized\u003c\/li\u003e\n\n\u003cli\u003e 483mm (19\") profile rails are depth adjustable and marked with the height unit\u003c\/li\u003e\n\n\u003cli\u003e Built-in depth supports provide stability\u003c\/li\u003e\n\n\u003cli\u003e Sliding cable entry with foam rubber seal in the floor and roof module\u003c\/li\u003e\n\n\u003cli\u003e Cable entry in the floor and roof with brush strips on the left and right\u003c\/li\u003e\n\n\u003cli\u003e Roof is prepared for a fan unit, including perforated cover\u003c\/li\u003e\n\n\u003cli\u003e Various grounding points in the housing for built-in components\u003c\/li\u003e\n\n\u003cli\u003e Incl. installation kit (screws, cage nuts, washers)\u003c\/li\u003e\n\n \u003cli\u003eDelivered fully assembled\u003c\/li\u003e\n\n\u003cli\u003e Installation depth for components min.-max.: 675-875 mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e \u003cspan\u003eFeatures\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv class=\"twocols\" id=\"techattrs-content\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Back door: Steel door, perforated, double opening\u003c\/li\u003e\n\n\u003cli\u003e Load capacity: 1000 kg\u003c\/li\u003e\n\n\u003cli\u003e Width: 800 mm\u003c\/li\u003e\n\n\u003cli\u003e Depth: 1000 mm\u003c\/li\u003e\n\n\u003cli\u003e Units: 42\u003c\/li\u003e\n\n\u003cli\u003e Cabinet type: Server cabinet\u003c\/li\u003e\n\n\u003cli\u003e Colour: black, RAL 9005\u003c\/li\u003e\n\n\u003cli\u003e Front door: Steel door, perforated, single opening\u003c\/li\u003e\n\n\u003cli\u003e Side panels: Both sides\u003c\/li\u003e\n\n\u003cli\u003e Assembled: yes\u003c\/li\u003e\n\n\u003cli\u003e IP protection class: IP20\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e \u003cspan\u003ePackage contents\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Set of grounding cables\u003c\/li\u003e\n\n\u003cli\u003e Installation kit (screws, cage nuts, washers)\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e incl. 4 adjustable feet and 4 castor wheels (already mounted)\u003c\/li\u003e\n\n\u003cli\u003e Installation kit for profile half cylinder\u003c\/li\u003e\n\n\u003cli\u003e 2 x key\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e \u003cspan\u003eDescription\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cdiv class=\"open\"\u003e\n\n\u003cdiv class=\"text twocol\"\u003e\n\n \u003cp\u003eOur Unique series server cabinets are designed for particularly convenient and flexible network cabling. Side brush inlets at the top and bottom (from 800 mm cabinet width), a slide-on inlet with foam seal and an additional brush inlet at the rear in the base plate enable versatile use in a variety of application scenarios. Single perforated front doors and double perforated rear doors, incl. swing handle with profile half cylinder, ensure better air circulation. The roof is equipped with a perforated cover that is attached above a structure for the easy integration of a fan module. Two pairs of galvanised 483 mm (19\") profile rails, labelled with height units that can be read in both directions, are provided on the inside. They are depth-adjustable and are fixed to additional depth supports in the cabinet. Each cabinet has a robust steel construction of up to 2.0 mm thick sheet steel. The colour is applied with an electrostatic powder coating in the standard colours grey (RAL 7035) and black (RAL 9005). Modular lockable and removable side walls (from 42U horizontally divided) and doors improve accessibility. The door opening direction can be changed. Furthermore, the cabinets can be completely dismantled if necessary thanks to their demountable construction.\u003c\/p\u003e\n\n\u003cdiv id=\"dlfiles\" class=\"tab-pane details-block\"\u003e\n\n \u003ch3\u003e\n\u003cspan\u003eDownloads\u003c\/span\u003e \u003c\/h3\u003e\n\n\u003cdiv class=\"attributes dl-horizontal row downloads\"\u003e\n\n\u003cdiv class=\"col-xs-12 col-sm-6 col-md-3\"\u003e\n\n\u003cdiv class=\"tab-pane details-block\" id=\"dlfiles\"\u003e\n\n\u003cdiv class=\"attributes dl-horizontal row downloads\"\u003e\n\n\u003cdiv class=\"col-xs-12 col-sm-6 col-md-3\"\u003e\n\n\u003ch4\u003e Datasheet\u003c\/h4\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003ca alt=\"Datasheet NL\" title=\"Datasheet NL\" href=\"https:\/\/www.assmann.com\/product-pdf\/4016032331766?PL=nl\" target=\"_blank\"\u003eDatasheet NL\u003c\/a\u003e \u003ca alt=\"FS-SRV MATRIX PL\" title=\"FS-SRV MATRIX PL\" href=\"https:\/\/ftp.assmann.com\/pub\/DN-\/DN-19SRV-42U-8-B___4016032331766\/DN-19SRV-42U-8-B_datasheet_pl_FS-SRV%20MATRIX%20PL_20230112.pdf?nodl=1\" target=\"_blank\"\u003e\u003c\/a\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-12 col-sm-6 col-md-3\"\u003e\n\n\u003ch4\u003e Manual\u003c\/h4\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \u003ca alt=\"Manual EN\" title=\"Manual EN\" href=\"https:\/\/ftp.assmann.com\/pub\/DN-\/DN-19SRV-42U-8-B___4016032331766\/DN-19SRV-42U-8-B_manual_en_Manual%20EN_20220523.pdf?nodl=1\" target=\"_blank\"\u003eManual EN\u003c\/a\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e \u003ca alt=\"Manual DE\" title=\"Manual DE\" href=\"https:\/\/ftp.assmann.com\/pub\/DN-\/DN-19SRV-42U-8-B___4016032331766\/DN-19SRV-42U-8-B_manual_de_Manual%20DE_20220523.pdf?nodl=1\" target=\"_blank\"\u003eManual DE\u003c\/a\u003e\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-12 col-sm-6 col-md-3\"\u003e\n\n\u003ch4\u003e QIG\u003c\/h4\u003e\n\n\u003cul\u003e\n\n \u003cli\u003e\n\u003ca alt=\"QIG Fan units EN DE\" title=\"QIG Fan units AND THE\" href=\"https:\/\/ftp.assmann.com\/pub\/DN-\/DN-19SRV-42U-8-B___4016032331766\/DN-19SRV-42U-8-B_qig_mul_QIG%20Fan%20units%20EN%20DE_20190114.pdf?nodl=1\" target=\"_blank\"\u003eQIG Fan units AND THE\u003c\/a\u003e \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"tab-pane details-block\" id=\"logistics\"\u003e\n\n\u003ch3\u003e \u003cspan\u003eLogistics\u003c\/span\u003e \u003c\/h3\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003ctable class=\"logistics\"\u003e\n\n\u003cthead\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003e\u003c\/th\u003e\n\n\u003cth\u003e Number\u003cbr\u003e (pcs)\u003c\/th\u003e\n\n\u003cth\u003e Weight\u003cbr\u003e (kg)\u003c\/th\u003e\n\n\u003cth\u003e Depth\u003cbr\u003e (cm)\u003c\/th\u003e\n\n\u003cth\u003e Width\u003cbr\u003e (cm)\u003c\/th\u003e\n\n\u003cth\u003e Height\u003cbr\u003e (cm)\u003c\/th\u003e\n\n\u003cth\u003e cm³\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003e Packaging unit cardboard\u003c\/th\u003e\n\n\u003ctd\u003e 1\u003c\/td\u003e\n\n\u003ctd\u003e 129.00\u003c\/td\u003e\n\n\u003ctd\u003e 105.00\u003c\/td\u003e\n\n\u003ctd\u003e 85.00\u003c\/td\u003e\n\n\u003ctd\u003e 205.00\u003c\/td\u003e\n\n\u003ctd\u003e 1,829,625.00\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003e Packaging unit inside\u003c\/th\u003e\n\n\u003ctd\u003e 1\u003c\/td\u003e\n\n\u003ctd\u003e 129.00\u003c\/td\u003e\n\n\u003ctd\u003e 105.00\u003c\/td\u003e\n\n\u003ctd\u003e 85.00\u003c\/td\u003e\n\n\u003ctd\u003e 205.00\u003c\/td\u003e\n\n\u003ctd\u003e 1,829,625.00\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003e Packaging unit single\u003c\/th\u003e\n\n\u003ctd\u003e 1\u003c\/td\u003e\n\n\u003ctd\u003e 129.00\u003c\/td\u003e\n\n\u003ctd\u003e 105.00\u003c\/td\u003e\n\n\u003ctd\u003e 85.00\u003c\/td\u003e\n\n\u003ctd\u003e 205.00\u003c\/td\u003e\n\n\u003ctd\u003e 1,829,625.00 \u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"morelogistics\"\u003e\n\n\u003cdiv\u003e\n\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n \u003cspan\u003eCustoms tariff number\u003c\/span\u003e :\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e9403208000\u003c\/span\u003e \n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"logistics\" class=\"tab-pane details-block\"\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv class=\"morelogistics\"\u003e\n\n\u003cdiv\u003e\n\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"safetynotes\" class=\"tab-pane details-block\"\u003e\n\n\u003ch3\u003e \u003cspan\u003eSafety regulations\u003c\/span\u003e\n\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Provide adequate ventilation to prevent the installed devices from overheating.\u003c\/li\u003e\n\n\u003cli\u003e Network cabinets should not be overcrowded and ventilation openings should not be blocked.\u003c\/li\u003e\n\n\u003cli\u003e Cables must be neatly laid and organized in cable ducts or trays.\u003c\/li\u003e\n\n\u003cli\u003e Use surge protectors to protect sensitive devices from power surges or lightning strikes.\u003c\/li\u003e\n\n \u003cli\u003eAvoid moisture or dampness while observing the respective IP protection class.\u003c\/li\u003e\n\n\u003cli\u003e Make sure that the enclosure and the devices used are properly grounded.\u003c\/li\u003e\n\n\u003cli\u003e In regions with frequent thunderstorm activity, professional lightning protection must be integrated into the power supply.\u003c\/li\u003e\n\n\u003cli\u003e To prevent uneven loading, always mount the heaviest equipment at the bottom of the cabinet.\u003c\/li\u003e\n\n\u003cli\u003e Disconnect installed devices from the power supply during maintenance or installation work. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"ASSMANN Electronic GmbH","offers":[{"title":"Default Title","offer_id":45462363668631,"sku":"SRV-42U-8-B","price":1099.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0642\/4641\/5511\/files\/DN19SRV42U8B_4016032331766_Front_1_RGB.jpg?v=1747212152","url":"https:\/\/cabledered.es\/en\/products\/42u-serverkast-met-geperforeerde-deuren-800x1000x2050mm-bxdxh-zwart","provider":"Netwerkkabel.eu","version":"1.0","type":"link"}